Hevi-Bar III

Special features

  • Finger-safe single pole insulated power feed system
  • Conductive material: aluminum/stainless steel
  • Metric dimensions

Main applications

  • Medium- to heavy-duty overhead cranes and process cranes

Standard application data

  • Nominal Current (at 100% duty cycle) [A]: 630 | 800 | 1000 | 1250
    (duty cycle at 20°C and 2 min = 100%)
  • Voltage Grade [V]: 600
  • Rail Length [mm]: 6000
  • External Dimensions (Pole) [mm]: 40 x 52
  • Operating Conditions: for indoor and weather-protected outdoor applications
    (EU: only in not publicly accessible areas)
  • Track Configuration: straight